霍爾德電子HD-TOC30型總有機碳(TOC)分析儀采用了高(gao)溫(wen)(wen)(wen)催化(hua)(hua)(hua)燃燒(shao)(shao)氧(yang)化(hua)(hua)(hua)法,將試(shi)樣連同凈化(hua)(hua)(hua)氣(qi)(qi)體(高(gao)純(chun)氧(yang))分(fen)別(bie)導入(ru)高(gao)溫(wen)(wen)(wen)燃燒(shao)(shao)管(guan)(guan)(guan)和(he)低溫(wen)(wen)(wen)反(fan)(fan)應(ying)管(guan)(guan)(guan)中(zhong),經(jing)(jing)(jing)高(gao)溫(wen)(wen)(wen)燃燒(shao)(shao)管(guan)(guan)(guan)的試(shi)樣被(bei)高(gao)溫(wen)(wen)(wen)催化(hua)(hua)(hua)氧(yang)化(hua)(hua)(hua),其(qi)中(zhong)的有機(ji)(ji)碳(tan)(tan)(tan)(tan)和(he)無(wu)機(ji)(ji)碳(tan)(tan)(tan)(tan)均轉化(hua)(hua)(hua)為(wei)二氧(yang)化(hua)(hua)(hua)碳(tan)(tan)(tan)(tan),經(jing)(jing)(jing)低溫(wen)(wen)(wen)反(fan)(fan)應(ying)管(guan)(guan)(guan)的試(shi)樣被(bei)酸化(hua)(hua)(hua)后,其(qi)中(zhong)的無(wu)機(ji)(ji)碳(tan)(tan)(tan)(tan)分(fen)解成二氧(yang)化(hua)(hua)(hua)碳(tan)(tan)(tan)(tan),兩種反(fan)(fan)應(ying)管(guan)(guan)(guan)中(zhong)生(sheng)產的二氧(yang)化(hua)(hua)(hua)碳(tan)(tan)(tan)(tan)經(jing)(jing)(jing)載氣(qi)(qi)輸送(song)依次(ci)被(bei)導入(ru)非(fei)分(fen)散紅(hong)外氣(qi)(qi)體檢(jian)測器NDIR中(zhong), CO?被(bei)檢(jian)測。從而(er)分(fen)別(bie)測得水中(zhong)的總(zong)(zong)碳(tan)(tan)(tan)(tan)(TC)和(he)無(wu)機(ji)(ji)碳(tan)(tan)(tan)(tan)(IC)。總(zong)(zong)碳(tan)(tan)(tan)(tan)與無(wu)機(ji)(ji)碳(tan)(tan)(tan)(tan)之差值,即為(wei)總(zong)(zong)有機(ji)(ji)碳(tan)(tan)(tan)(tan)(TOC)。即:TOC=TC-IC

1. 環(huan)(huan)境(jing)(jing)監(jian)測(ce)(ce):總(zong)有機碳分析儀可以(yi)檢測(ce)(ce)水體、土(tu)壤(rang)和空氣中的(de)有機物質含量(liang),用于環(huan)(huan)境(jing)(jing)監(jian)測(ce)(ce)、環(huan)(huan)境(jing)(jing)評(ping)價和環(huan)(huan)境(jing)(jing)治(zhi)理(li)等。
2. 水質(zhi)檢測(ce):在飲用水、污水處理(li)、水池和地下(xia)水等(deng)領域中,總有(you)機碳分析儀(yi)可作為重(zhong)要的(de)水質(zhi)檢測(ce)儀(yi)器來(lai)使(shi)用。
3. 食(shi)品(pin)檢測:總(zong)有機碳(tan)分(fen)析儀(yi)可以(yi)檢測食(shi)品(pin)中的有機物質(zhi)含量,對于規范食(shi)品(pin)和(he)飲品(pin)生產過程(cheng)、確保(bao)食(shi)品(pin)安全具(ju)有重要作用。
4. 生(sheng)命(ming)科學:在醫(yi)藥研發、生(sheng)物科學實驗(yan)等領域,總有機(ji)碳(tan)分析儀(yi)可用于檢測有機(ji)物質的含量。
1.高(gao)溫催化(hua)氧化(hua),對(dui)于(yu)(yu)難消解的(de)有機碳,也能高(gao)效率的(de)氧化(hua),使得產品(pin)(pin)易于(yu)(yu)分(fen)析高(gao)濃度(du)的(de)TOC樣品(pin)(pin);
2.快速分析(xi)(1~4min);
3.更高的安全性,燃燒爐加熱采用多重保護,獨立于(yu)溫度(du)控制系統(tong)的過熱保護電路(lu),過熱能自動切(qie)斷加熱,確保產品安全;
4.實時流量監(jian)視,保持流路穩定(ding),保證數據的可(ke)靠性(xing);
5.管路(lu)多方位(wei)清洗和吹掃(sao),可(ke)以根據需求,按操(cao)作要求清洗內部回(hui)路(lu),大大減少(shao)了故(gu)障發生率及儀(yi)器維護時間;
6.儀器自動(dong)排廢,自動(dong)排酸(suan)和(he)進酸(suan),進酸(suan)量(liang)控制穩定;
7.較(jiao)少的樣品和試(shi)劑(ji)消(xiao)耗,每(mei)次(ci)測量需消(xiao)耗高純水0.5μL,酸試(shi)劑(ji)2ml(IC測試(shi)時),高純氧氣約2000ml(標況下,流速(su)100ml/min,通氣時間20min.);
8.NDIR檢測(ce)(ce)器的CO?檢測(ce)(ce)有良(liang)好(hao)的線(xian)性(xing)和高準確性(xing)。CO?信(xin)號轉化成為一(yi)個峰曲線(xian),然后(hou)再(zai)由內置(zhi)的數據處理器計算出(chu)TOC數值(zhi)(TC與(yu)IC之差);
9.催化(hua)(hua)燃(ran)燒(shao)(shao)氧化(hua)(hua)法氧化(hua)(hua)能力強(qiang),幾乎可以(yi)氧化(hua)(hua)所(suo)有(you)的(de)(de)有(you)機物且性(xing)能穩(wen)定(ding)(ding)。680℃燃(ran)燒(shao)(shao)法幾乎是在所(suo)有(you)鹽份(fen)的(de)(de)融點(dian)以(yi)下,這樣(yang)可以(yi)延(yan)長(chang)催化(hua)(hua)劑和燃(ran)燒(shao)(shao)管的(de)(de)壽命,這一點(dian)尤其是在測定(ding)(ding)對象是含鹽份(fen)的(de)(de)水(shui)樣(yang)時很重(zhong)要(yao);
10.儀器使用高分辨率7寸觸摸寬(kuan)屏(ping),采用智能系(xi)統,全中文(wen)界(jie)面,使得(de)界(jie)面友好,操作簡便。
1.測定(ding)范圍:0~1000mg/L(非稀釋(shi)狀態),稀釋(shi)狀態可達到0~30000mg/L;
2.重復性:≤3%;
3.示值誤差(cha):TC:±0.1%F.S或(huo)±5%(取較大(da)者);
IC:±0.1%F.S或±4%(取(qu)較大(da)者);
4.線(xian)性(xing):R2≥99.9%;
5.檢出下限:0.5mg/L;
6.分析時間:2~4min;
7.注 射 量:10μL~500μL;
8.外部存儲:U盤;
1.電源:AC220V±10%50/60Hz(要求可靠(kao)接地(di));
2.功(gong)率(lv):電爐升溫時為1000W;
3.環境溫度:0~40℃;
4.相對濕度(du):10~85%;
5.設(she)置場所(suo):室內;
6.氣源:高純氧氣(≥99.999%);
7.高(gao)純水:無二氧化(hua)碳水(TOC≤0.5mg/L);
8.酸試劑(ji):10%磷酸;
9.儀器放(fang)置:四周(zhou)須有(you)20cm空間,以備散熱,上(shang)方不可(ke)堆放(fang)物品(pin);
10.燃燒溫度(du):680℃~1200℃;
總磷超(chao)標的主要原因(總磷超(chao)標的處(chu)理方法)
2023-01-10氯化(hua)鋅檢測(ce)儀(yi)使用步驟(氯化(hua)鋅對人(ren)體的危害)
2024-10-23BOD檢(jian)測(ce)標準(zhun)限值(水質BOD檢(jian)測(ce)的注意事項)
2025-06-17余(yu)氯是什么(余(yu)氯的國(guo)家(jia)標準是多少)
2023-01-31硅酸根(gen)分(fen)析儀工作原理(硅酸根(gen)分(fen)析儀檢(jian)定(ding)規程)
2025-12-18如何(he)正確使用(yong)水(shui)質(zhi)檢(jian)測(ce)儀(yi)器對水(shui)體進(jin)行監測(ce)(水(shui)質(zhi)檢(jian)測(ce)儀(yi)的選擇)
2024-09-26手(shou)持式二氧化氯(lv)檢(jian)測儀怎么用(手(shou)持式二氧化氯(lv)檢(jian)測儀維護方法)
2023-11-14飲用水濁度的檢測標準(水質濁度檢測方(fang)法原理)
2024-03-20